[Single-channel Co or Co2 or So2 or NOx]
Model 1010 for CO or C02, 1021 for So2 and 1030 for NOx


With no sampling system to maintain, 1000 cross-duct monitors are easy to install and simple to operate, vital for a plant where there may be little or no technical support available.

The 1000 analyser may be used as a complete stand-alone monitor or as part of an integrated emission monitoring, logging and reporting system. The instrument is particularly suited to large and dirty processes.

Summary Specification

Span: Co & NO selectable from 0-100 ppm to 0-10000 ppm, within the range 200 to 6000 ppm.meter at STP
So2 Selectable from 0-100 ppm to 0-10000 ppm, within the range 200 to 6000 ppm.meter at STP

Display Units: ppm; mg/m3 (measured); mg/Nm3 (normalized)
Averaging: 4 averages selectable from 10 seconds to 30 days

Accuracy: + 2% of measurement or + 5ppm whichever is greater

Outputs:
Analog: 4~20mA isolated, 500 ohms max;
High Alarm: Volt free contact;
Data Valid: Volt free contact (both rated @ 10 Amps @ 250 V)

Inputs:
Oxygen: 4~20mA; Temp: 4~20mA; Pressure: 4~20mA;
Plant Status contact: Volt free contact
Serial Port: For remote instrument operation, normalizing inputs and outputs

Path length: 0.5 to 8 meters
Flue gas temperature: 0 to 300 deg C
Construction: Cast Aluminum, fully sealed to IP65
Transmitter: Electrically heated Silicon Nitride Cylinder
Detector: Lithium Tantalite Pyro-electric detector
Ambient temperature limits: -20 deg C to 70 deg C
Power Requirements: 85 to 132/170 to 264 V AC, 50/60 Hz, and 50 VA
Air purge consumption: 1.0 l/s @ 1 bar (compressed air) 5 l/s (blower air)

The range of the output span is quoted in ppm.meter.


Low cost single gas analyzer for small, medium and large Boilers

Simple installation with only FOUR modules, Transmitter, Receiver, Power supply and Signal Processor, all NEMA 4X rated

Most suitable for emissions monitoring as well as closed loop online insitu combustion efficiency control with 10 secs response time



Minimal lens contamination

- High-efficiency air purges to maintain optical efficiency

Automatic on-line zero calibration
- Continual correction using integral reference gas cell

Real-time normalization
- To standard reference conditions

Low maintenance overheads
- Only simple, infrequent checks to windows required

Choice of data presentation
- Ppm, mg/m3 and mg/Nm3

Optional Independent verification
- Using certified test cellsor filters

One-year parts and labor warranty for complete peace of mind



Download PDF