Fully purged transducers with
no moving components make the system highly reliable and minimize
maintenance requirements. The instrument is ideally suited
to monitoring the flow rate of hot, dirty gases.
Each transducer unit consists
of a broadband infrared detector, a lens to focus the radiation
received on the detector and a pre-amplification circuit board,
all housed within a fully sealed, epoxy-coated aluminum enclosure.
The transducers are supplied with air purge units to maintain
the cleanliness of the transducer windows.
Specification
Measurement Range selectable to 50m/s
Response selectable 10 seconds
to 30 days
Accuracy < ±2% of
measurement
Serial Port data bus I/P &
O/P.
Construction fully sealed
(IP65) epoxy-coated Aluminum enclosures
Ambient Temperature Limits
–20 c to +70 C
Power Requirements SCU 86-264V
AC max. V-CEM 48V DC (from SCU)